This kit provides both positive and negative control RNA samples to validate the globin-reduction procedure in conjunction with the GeneChip® Blood RNA Concentration Kit (P/N 900585).
The Globin-Reduction RNA Controls box contains 2 vials of RNA:
| Reagent | Description |
|---|---|
| Jurkat RNA | Purified from Jurkat cells that contain negligible amounts of globin mRNAs, this control represents RNA purified from the leukocyte fraction of whole blood. |
| Jurkat + Globin RNA | This control RNA is the Jurkat RNA described above but spiked with in vitro-synthesized, polyadenylated globin transcripts. The Jurkat + Globin RNA control mimics RNA purified from unfractionated whole blood. |
The kit provides sufficient Jurkat RNA and Jurkat + Globin RNA for six reactions each, for a total of twelve reactions.
Recommended globin-reduction controls and their expected results:
| Sample | Rx | Globin Reduction | Total RNA Input (µg) | Replicates | Expected Result |
|---|---|---|---|---|---|
| Jurkat RNA | 1 | No | 2 | 3 | Optimal GeneChip array results are expected. This reaction is used as a reference to determine success of the GeneChip Target Labeling. |
| 2 | Yes | 2 | 3 | Optimal GeneChip array results are expected. This reaction is used to verify that the globin reduction procedure does not affect non-globin transcripts. | |
| Jurkat RNA + Globin RNA | 3 | No | 2 | 3 | Sub-optimal GeneChip results are expected due to a loss in assay sensitivity. This reaction is used to demonstrate the effects of high amounts of globin mRNAs on array analysis. |
| 4 | Yes | 2 | 3 | Optimal GeneChip array results similar to those obtained using the Jurkat RNA control are expected. This reaction is used to demonstrate the increase in assay sensitivity due to the globin reduction procedure. |
Data Sheets
Standardized Assays and Reagents for GeneChip Expression Analysis (pdf, 3.02 MB)
Technical Notes
| Part # | Description | Details |
|---|---|---|
| 900586 | GeneChip® Globin-Reduction RNA Controls | Sufficient for 12 reactions |
Related Products
| Part # | Description | Details |
|---|---|---|
| 900585 | GeneChip® Blood RNA Concentration Kit | Sufficient for 30 samples |
| 900431 | GeneChip® One-Cycle cDNA Synthesis Kit | Sufficient for 30 reactions |
| 901229 | GeneChip® 3' IVT Express Kit | Sufficient for 30 reactions |
FAQs
Gene Expression Assay and Data Analysis
Manuals
Globin-Reduction Protocol (pdf, 495 KB)
Probe Set Data in MAGE-ML Format
Material Safety Data Sheets
Globin-Reduction RNA Controls (zip, 30 KB)
Package Inserts
Globin-Reduction RNA Controls (pdf, 76 KB)
Additional Support