Products & Services
DMET™ Plus Premier Pack

News and Events

12/9/2008

Affymetrix Technology Powers Cincinnati Children's Hospital's Innovative Test for Jaundice

12/8/2008

Affymetrix Completes Acquisition of Panomics

View All >

Plant and Animal Genome XVII Conference

1/10/2009-1/14/2009

View All >

Achieving ROI in Personalized Medicine: Barriers, Incentives, and Pathways to Commercialization

1/27/2009-1/28/2009

GeneChip® Globin-Reduction RNA Controls

This kit provides both positive and negative control RNA samples to validate the globin-reduction procedure in conjunction with the GeneChip® Blood RNA Concentration Kit (P/N 900585).

The Globin-Reduction RNA Controls box contains 2 vials of RNA:

Reagent Description
Jurkat RNA Purified from Jurkat cells that contain negligible amounts of globin mRNAs, this control represents RNA purified from the leukocyte fraction of whole blood.
Jurkat + Globin RNA This control RNA is the Jurkat RNA described above but spiked with in vitro-synthesized, polyadenylated globin transcripts. The Jurkat + Globin RNA control mimics RNA purified from unfractionated whole blood.

The kit provides sufficient Jurkat RNA and Jurkat + Globin RNA for six reactions each, for a total of twelve reactions.

Recommended globin-reduction controls and their expected results:

Sample Rx Globin Reduction Total RNA Input (µg) Replicates Expected Result
Jurkat RNA 1 No 2 3 Optimal GeneChip array results are expected. This reaction is used as a reference to determine success of the GeneChip Target Labeling.
2 Yes 2 3 Optimal GeneChip array results are expected. This reaction is used to verify that the globin reduction procedure does not affect non-globin transcripts.
Jurkat RNA + Globin RNA 3 No 2 3 Sub-optimal GeneChip results are expected due to a loss in assay sensitivity. This reaction is used to demonstrate the effects of high amounts of globin mRNAs on array analysis.
4 Yes 2 3 Optimal GeneChip array results similar to those obtained using the Jurkat RNA control are expected. This reaction is used to demonstrate the increase in assay sensitivity due to the globin reduction procedure.

Back to Top >

Part # Description Details
900586 GeneChip® Globin-Reduction RNA Controls Sufficient for 12 reactions

Related Products

Part # Description Details
900585 GeneChip® Blood RNA Concentration Kit Sufficient for 30 samples
900431 GeneChip® One-Cycle cDNA Synthesis Kit Sufficient for 30 reactions
901229 GeneChip® 3' IVT Express Kit Sufficient for 30 reactions